276°
Posted 20 hours ago

MEM Memera 2000 - ALB161 - 16a Type B Single Pole MCB

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

Qwikline – This is the most common Square D breaker and the part numbers will always start QO. Available in types 2,3 & 4 with M6 or M9 breaking capacities for early BS3871 breakers or types B,C & D with 6kA or 10kA breaking capacities. These styles have the push-fit electrical connection and push-fit mechanical connection. These are available in single, double and triple pole. Initially the range was made to BS3871 standards so Types 2 & 3 were available from 6A up to 63A in single and triple pole. RCBO's were also available but they were initially referred to as MCB/RCD units as the term RCBO was not really established as yet. Memshield 2 – These are also a commercial breaker and come in types B,C & D. These also will fit into all Memera 2000 range boards. Not all pods are the same, some have long leads for triple pole boards and some have short leads for use in domestic boards. Also worth mentioning that the pods will fit the Memera 2000 range of MCB's as well but only the part numbers that start ALB or ALC.

Memshield 1 – These are a commercial breaker and come in various types (Type 2,3,B,C & D) depending upon the age. Most are M9 rated. Confused? Well it gets worse because by the time that Delta/Eaton decided that they needed to manufacturer some of the older products to keep the peace with customers the British Standard BS3871 had changed. Previously all MCB's had been marked with a ‘Type' (either 1,2,3 or 4) but BS3871 had changed so that Type 1 MCB's were no longer used and Types 2,3 & 4 were now Types B,C & D. As with MCB's all MCCB's were manufactured by Delta and either branded MEM or Bill. They are identical apart from the logo and and a slight difference in the part number. You won't find any branded Delta, they never used that branding on any moulded case breakers. Domae – This was the final range of MCB's branded as Square D. Unusually they are not the push-fit type which was what Square D was really known for. This range just uses a standard din-rail clips and was a ‘competitive' product aimed purely for the domestic market. Later versions were branded Schneider but are identical to the Square D. However, just to add a little confusion, some MCB's were discontinued whilst under the MEM brand but due to complaints from customers, specifiers and electrical wholesalers the company had to start manufacturing again. Some of these products are branded Delta and from 2003 some of these products are branded Eaton when they company was bought out yet again.All MCCB's in MEM's Memshield 2 range or Bill's Talisman Plus range are branded as such. Even though Eaton bought out Delta in 2003 they maintained the old branding until they came out with the latest range, Memshield 3. Even though they are using the Memshield brand all breakers are now marked as Eaton. Still Confused? So now you have a range of circuit breakers that are either branded MEM,Delta,Bill or Eaton. They may me marked either Type 2,3,4 or Type B,C,D. Some have a printed wrap around label and some have silk screen printing direct on the MCB.

Otherwise, I'm not quibbling the need for proper spur to garage, which will separate off two freezers from kitchen, but how do you people feel about this diagnosis? My own insulation tests with mega meter to each unplugged appliance have found no resistance issues, which given he found no wiring issues, leaves no obvious cause except as he thinks maybe too much total freezer earth leakage. Intermittent faults like tripping can send you mad as we all know, is this a good course of action? but mounted above the old Wylex fuse boxes, however done before the rules changed as to electrical equipment in the control of an ordinary person. But still today we have isolators before the CU to comply with HSE rules an live working, so not sure if we can still mount SPD or RCD in separate box before or after main CU? Fortunately the situation with Bill and MEM MCCB's is not as confusing. Firstly MCCB's are made to a different standard to MCB's, BS60947-2. Whilst that standard has been updated to allow for new technologies it still remains as the current British Standard. The Polestar range of breakers was unique because they had a higher than usual fault rating of 16kA where standard breakers at the time were 6kA and 9kA. What this meant was that Polestar could be used in areas where a high kA was required without having to use Moulded Case Breakers (MCCB's) or HRC fuse carriers. Crabtree Polestar breakers are also unique in that they are much wider (25mm) than a standard mcb (18mm). This extra width was needed for the bigger arc splitter to allow for a higher kA rating. The older RCD does seem to be affected by spikes, so likely a SPD would stop it, but a consumer unit is a type tested distribution unit, and to retain the type testing only items recommended by the manufacturer can be used, even if they seem to fit.

Arc Fault Detection Devices (AFDD+)                                                                                       

Loadcentre – This was a new range introduced by Schneider but using the brand name of Square D. This is more of a commercial range with types B,C & D available (B type only in single pole). They have a breaking capacity of 10kA and. Later versions were branded as Schneider but are identical to the Square D. These will also fit the Qwikline II boards. Memera 2000AD – These have a narrow terminal and only fit boards specifically marked Memera 2000AD. They won't fit in older boards.

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.
New Comment